However if our effective roof area were 50 m 2 then we would not be able to use a level half round gutter with a stop end outlet ie the downpipe at one end of the gutter rather than in the middle.
How many downpipes for roof area uk.
The length of the roof is 8 7m for this square house as 8 7m x 8 7m is 76m total floor space.
Because this is only one half of the roof we will need to double this number to find the entire roof area 121 45m.
The answers for downpipe size are in mm.
Lg 10 133 therefore reduction factor 0 86 d 0 1 gutter capacity x reduction factor 2 84 x 0 86 2 44 l s therefore the proposed system is suitable.
Roof area m gutter flow litres sec roof area m downpipe at centre half round 76mm 0 7 34 0 8 38 112mm 1 8 86 2 6 125 squareflo 3 2 154 3 8 182 125 68mm downpipe 3 8 182 4 6 221 82mm downpipe 4 0 191 4 9 235 regency 4 2 202 4 7 226 highflo 5 4 258 6 0 289 stormflo 110mm 11 1 534 12 4 598 160mm 12 5 601 14 0 673 downpipe at end half.
The roof slope height is 6 98m.
Select 100 x 50 rectangular downpipe.
A rainwater downpipe is a pipe that is used to direct rainwater away from a building typically from roof guttering to a drainage system it is sometimes also referred to as a downspout drain spout roof drain pipe or leader.
Divide the main roof into catchments of this size and any left over area can be entered again to find a down pipe size for this smaller area.
How many downpipes do you need.
The building regulation s part h drainage and water disposal requires that adequate provision is made for rainwater to be carried from the roof of buildings.
Frequency and positioning of outlets downpipes calculate the number of outlets per run.
8 7m x 6 98m 60 73m.
It is the roof area the pitch of the roof and the number of drops downpipes coming down from outlets in the guttering around the building determine the flow we will need to know these to calculate the flow capacity for you.
So for our example the half roof area is as follows.
Sizing downpipes downpipes are sized for the areas that discharge into them.
This is because larger roofs require bigger volumes of water to be diverted away from them during periods of rainfall.
63 mm diameter downpipes.
Usually the size for the largest collection area on the roof is used to size downpipes throughout.
Min number of downpipes roof catchment area.
Determine minimum number of downpipes.
The program will calculate the most suitable circular and rectangular downpipe sizes.
Using clause e1 table 5 see figure 2 at a roof pitch of 45 for this example.
Figure 1 an example of a roof with a total plan area of 98 m.
Design area effective area 5 x 10 x 1 29 64 5m run off 64 5m x 0 022 l s per m 1 42 l s from chart 125 x 100 gutter with 76 ø downpipe appears suitable but check.
To calculate the minimum number of downpipes divide the roof catchment area by the allowable maximum catchment per downpipe.
The number of downpipes you need will depend on the size of your roof and your chosen style of guttering.